Description
|
project |
Specification |
|
Power specifications |
DC24V±10% |
|
Range |
±1000um |
|
Resolution |
0.1um |
|
Full scale linearity error |
≤0.1% |
|
Repeatability error |
≤1um |
|
Operating temperature range |
-10℃~50℃ |
|
Data collection method |
Parallel port communication |
|
Nonlinear |
0.001%F.S |
|
Time Drift |
0.005% F.S |
|
Input sensitivity |
0.004uV/d |
|
Comprehensive accuracy |
0.1% |